Utah Home Systems



Definitions
NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection
A Acceptable Functional with no obvious signs of defect.
NP Not Present Item not present or not found.
NI Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible, or disconnected at time of inspection.
M Marginal Item is not fully functional and requires repair or servicing.
D Defective Item needs immediate repair or replacement. It is unable to perform its intended function.


General Information
Property Information
Property Address Sample
City Sample State Utah Zip xxxxx
Contact Name Sample
Phone xxx-xxx-xxxx Fax none
E-Mail Sample
Client Information
Client Name Sample
Client Address Sample
City Sample State Utah Zip xxxxx
Phone xxx-xxx-xxxx Fax none
E-Mail Sample
Inspection Company
Inspector Name Richard Canfield
Company Name: Utah Home Systems
Company Address: PO Box 292
City Honeyville  State UT  Zip 84314  
Phone 435-225-5911 Fax 435-279-8868
E-Mail richard@utahhomesystems.com
File Number Sample
Amount Received Sample
Conditions
Others Present None Property Occupied No
Estimated Age 14 years Entrance Faces South
Inspection Date Sample
Start Time 3:45pm End Time 7:45pm
Electric On  X Yes   _ No
Gas/Oil On  _ Yes   X No
Water On   X Yes   _ No
Temperature 72
Weather Clear Soil Conditions Damp
Space Below Grade Basement
Building Type Single family Garage Attached
Sewage Disposal City How Verified Buyers Agent
Water Source City How Verified Buyers Agent
Additions/Modifications N/A
Permits Obtained N/A How Verified N/A


Lots and Grounds

A NP NI M D
1.X____ Walks: Concrete
2.X____ Steps/Stoops: Concrete
3.X____ Patio: Concrete
4.X____ Deck: Stained wood
5.____X Porch: Concrete - Front porch is settling away from foundation. A qualified contractor is recommended to evaluate and estimate repairs
6.X____ Vegetation: Shrubs/Weeds
7.X____ Retaining Walls: Stone
8.X____ Grading: Stair stepped
9.____X Window Wells: Drain not present - Well on west side is not deep enough for proper drainage.
10.X____ Driveway: Concrete - Concrete pitted and chipped, normal wear.
11.X____ Lawn Sprinklers: Front and back yard


Exterior Surface and Components

A NP NI M D
Balance of surface other than front brick Exterior Surface
1.___X_ Type: Vinyl siding - Some small holes and missing bits on back side of home.
South Exterior Surface
2.___X_ Type: Brick veneer - Cracks on southwest corner above setting porch.
3.X____ Fascia: Aluminum
4.X____ Soffits: Aluminum Vented
5.X____ Door Bell: Hard wired - Front door only
6.___X_ Entry Doors: Metal - Rear French door rubs and not sealed properly.
7._X___ Patio Door:
8.X____ Windows: Aluminum slider
9.X____ Storm Windows: Aluminum framed tempered glass
10.X____ Window Screens: Vinyl mesh
11.X____ Basement Windows: Aluminum slider
12.X____ Exterior Lighting: Surface mount
13.____X Exterior Electric Outlets: 110 VAC GFCI - Outlet at back door is not working.
14.____X Hose Bibs: Rotary - Rear bib is not working properly. Leaks into basement, A licensed plumber is recommended to evaluate and estimate repairs
15.X____ Gas Meter: West side of home
16.X____ Main Gas Valve: Located at gas meter


Outbuilding

A NP NI M D
Outbuilding
1._X___ Exterior Surface:
2._X___ Roof:
3._X___ Roof Structure:
4._X___ Ceiling:
5._X___ Walls:
6._X___ Floor:
7._X___ Foundation:
8._X___ Doors:
9._X___ Windows:
10._X___ Electrical:
11._X___ Plumbing:
12._X___ HVAC Source:
13._X___ Gutters:
14._X___ Downspouts:
15._X___ Leader/Extension:


Roof

A NP NI M D
Main Roof Surface
1. Method of Inspection: On roof
2.X____ Unable to Inspect: 0%
3.____X Material: Asphalt shingle - Missing shingles, exposed felt paper, A qualified roofing contractor is recommended to evaluate and estimate repairs
4. Type: Gable
5. Approx Age: 14 years
6.X____ Flashing: Galvanized
7.___X_ Valleys: Asphalt shingle - Ridge shingles are cracked, A qualified roofing contractor is recommended to evaluate and estimate repairs
8._X___ Skylights:
9.X____ Plumbing Vents: ABS
10._X___ Electrical Mast:
11.X____ Gutters: Aluminum
12.X____ Downspouts: Aluminum
West Chimney
13.____X Chimney: Vinyl and frame covered three wall pipe - Broken vinyl, A qualified contractor is recommended to evaluate and estimate repairs
14.X____ Flue/Flue Cap: Metal
15.X____ Chimney Flashing: Galvanized


Garage/Carport

A NP NI M D
Side Garage
1. Type of Structure: Attached Car Spaces: 2
2.X____ Garage Doors: Metal
3.X____ Door Operation: Mechanized
4.X____ Door Opener: Sears
5.X____ Exterior Surface: Vinyl siding, and brick
6.X____ Roof: Asphalt shingle
7.__X__ Roof Structure:
8.X____ Service Doors: Metal
9.X____ Ceiling: not painted
10.X____ Walls: Exposed framing
11.X____ Floor/Foundation: Poured
12._X___ Hose Bibs:
13.X____ Electrical: 110 VAC GFCI
14._X___ Heating:
15.X____ Windows: Aluminum slider
16.X____ Gutters: Aluminum
17.X____ Downspouts: Aluminum


Electrical

A NP NI M D
1. Service Size Amps: 100 Volts: 220 VAC
2.X____ Service: Aluminum
3.X____ 120 VAC Branch Circuits: Copper
4.____X 240 VAC Branch Circuits: Copper - Dryer circuit shows sign of arcing under the electrical panel cover.
5.X____ Aluminum Wiring: Not present
6.X____ Conductor Type: Romex
7.X____ GFCI: Present
8.X____ Ground: Plumbing and rod in ground.
9.____X Smoke Detectors: Present on all finished levels of the home - These detectors appear to be the original equipment. They should be replaced. None in basement.
Basement main Electric Panel
10.____X Manufacturer: Square D - Cracked insulation and signs of arcing on dryer circuit. Recommend further inspection by a qualified electrician.
11. Max Capacity: 125 Amps
12.X____ Main Breaker Size: 100 Amps
13.X____ Breakers: CU/AL
14._X___ Fuses:
15. Is the panel bonded?  X Yes _ No


Structure

A NP NI M D
1.X____ Structure Type: Wood frame
2.X____ Foundation: Poured
3.____X Differential Movement: Crack with displacement - southwest corner of front porch.
4.X____ Beams: Solid wood
5.X____ Bearing Walls: Frame
6.X____ Joists/Trusses: 2x10
7.X____ Floor/Slab: Poured slab
8.___X_ Stairs/Handrails: Wood stairs with wood handrails - Upstairs hand rail loose.
9.X____ Subfloor: Dimensional wood


Attic

A NP NI M D
Main Attic
1. Method of Inspection: In the attic
2.X____ Unable to Inspect: 25%
3.X____ Roof Framing: 2x4 Truss
4.X____ Sheathing: Dimensional wood
5.X____ Ventilation: Gable and soffit vents
6.X____ Insulation: Blown in
7.X____ Insulation Depth: 20"
8._X___ Vapor Barrier:
9._X___ Attic Fan:
10._X___ House Fan:
11.X____ Wiring/Lighting: 110 VAC lighting circuit
12.X____ Moisture Penetration: No penetration detected
13.X____ Bathroom Fan Venting: Electric fan


Basement

A NP NI M D
Main Basement
1.X____ Unable to Inspect: 0%
2.X____ Ceiling: Exposed framing
3.____X Walls: Concrete - Signs of water penetration on the north wall. This is from a leaking hose bib on the rear of the home.
4.X____ Floors: Poured
5.X____ Floor Drain: French drain
6.X____ Doors: Hollow wood
7.___X_ Windows: Aluminum slider - South west corner room window well needs to been dug out to allow proper drainage.
8.___X_ Electrical: 110 VAC GFCI - One broken duplex cover by electrical panel
9.X____ HVAC Source: Air exchange ventilation
10.X____ Ventilation: Windows
11._X___ Insulation:
12._X___ Vapor Barrier:
13._X___ Sump Pump:
14.___X_ Moisture Location: Tested all walls - Rear hose bib leaks into basement, A qualified contractor is recommended to evaluate and estimate repairs
15.X____ Bsmt Stairs/Railings: Wood stairs with wood handrails


Crawl Space

A NP NI M D
Crawl Space
1. Method of Inspection:
2._X___ Unable to Inspect:
3._X___ Access:
4._X___ Moisture Penetration:
5. Moisture Location:
6._X___ Moisture Barrier:
7._X___ Ventilation:
8._X___ Insulation:
9._X___ Vapor Barrier:
10._X___ Sump Pump:
11._X___ Electrical:
12._X___ HVAC Source:


Air Conditioning

A NP NI M D
On the roof/evaporative cooler) AC System
1.X____ A/C System Operation: Appears serviceable
2._X___ Condensate Removal:
3.__X__ Exterior Unit: Unknown manufacturer
4. Area Served:Approximate Age: 14 years
5. Fuel Type:Temperature Differential:
6. Type:Capacity:
7._X___ Visible Coil:
8._X___ Refrigerant Lines:
9._X___ Electrical Disconnect:
10._X___ Exposed Ductwork:
11.X____ Blower Fan/Filters: Appears serviceable
12.X____ Thermostats: Individual


Fireplace/Wood Stove

A NP NI M D
Main floor great room Fireplace
1.__X__ Freestanding Stove:
2.__X__ Fireplace Construction:
3. Type:
4.__X__ Fireplace Insert:
5.__X__ Smoke Chamber:
6.__X__ Flue:
7.__X__ Damper:
8.__X__ Hearth:


Heating System

A NP NI M D
Basement Heating System
1.___X_ Heating System Operation: Appears functional - No green sticker
2. Manufacturer: Tempstar
3. Model Number: 867768172 Serial Number: L911210960
4. Type: Forced air Capacity: 100,000 BTUHR
5. Area Served: Whole building Approximate Age: 14 years
6. Fuel Type: Natural gas
7.X____ Heat Exchanger: 4 Burner
8. Unable to Inspect: 0%
9.X____ Blower Fan/Filter: Direct drive with disposable filter
10.X____ Distribution: Metal duct
11.X____ Circulator: Gravity
12.X____ Draft Control: Automatic
13.X____ Flue Pipe: Single wall
14.X____ Controls: Limit switch
15.X____ Devices: N/A
16._X___ Humidifier:
17.X____ Thermostats: Individual
18._X___ Fuel Tank:
19.X____ Suspected Asbestos: No


Plumbing

A NP NI M D
1.X____ Service Line: Copper
2.X____ Main Water Shutoff: Basement
3.X____ Water Lines: Copper
4.X____ Drain Pipes: ABS
5.X____ Service Caps: Accessible
6.X____ Vent Pipes: ABS
7.X____ Gas Service Lines: Cast iron
Basement Water Heater
8.__X__ Water Heater Operation:
9. Manufacturer: Covered, unable to inspect
10. Model Number: C540NORT6DF Serial Number: J91768634
11. Type: Natural gas Capacity: 40 Gal.
12. Approximate Age: 16 years Area Served: Whole building
13.X____ Flue Pipe: Single wall
14.X____ TPRV and Drain Tube: Copper
15.____X Seizmic bracing None


Bathroom

A NP NI M D
2nd Floor Hall Bathroom
1.X____ Ceiling: Texture paint
2.X____ Walls: Paint
3.X____ Floor: Linoleum
4.X____ Doors: Hollow wood
5.X____ Windows: Aluminum slider
6.X____ Electrical: 110 VAC GFCI
7.X____ Counter/Cabinet: Laminate and wood
8.X____ Sink/Basin: Molded single bowl
9.X____ Faucets/Traps: Price pfister
10.____X Tub/Surround: Cast iron tub and ceramic tile surround; - Drain stop not working
11.X____ Toilets: Crane
12.X____ HVAC Source: Air exchange ventilation
13.___X_ Ventilation: Window
Master Bathroom
14.X____ Ceiling: Texture paint
15.X____ Walls: Paint
16.X____ Floor: Linoleum
17.X____ Doors: Hollow wood
18.X____ Windows: Aluminum slider
19.X____ Electrical: 110 VAC GFCI
20.X____ Counter/Cabinet: Laminate and wood
21.X____ Sink/Basin: Molded single bowl
22.X____ Faucets/Traps: Price pfister
23.X____ Tub/Surround: Fiberglass tub
24.X____ Shower/Surround: Tile pan and surround
25.X____ Toilets: Crane
26.X____ HVAC Source: Air exchange ventilation
27.X____ Ventilation: Electric ventilation fan
Main level half bath Bathroom
28.X____ Ceiling: Texture paint
29.X____ Walls: Paint
30.X____ Floor: Linoleum
31.X____ Doors: Hollow wood
32.X____ Windows: Aluminum slider
33.X____ Electrical: 110 VAC GFCI
34.X____ Counter/Cabinet: Laminate and wood
35.X____ Sink/Basin: Molded single bowl
36.X____ Faucets/Traps Price Pfister
37.X____ Toilets: Crane
38.X____ HVAC Source: Air exchange ventilation
39.___X_ Ventilation: Window


Kitchen

A NP NI M D
1st Floor Kitchen
1.X____ Cooking Appliances: Many
2.X____ Ventilator: Magic chef
3.___X_ Disposal: Waste King - Makes noise like bad bearings
4.X____ Dishwasher: Kenmore
5. Air Gap Present?  X Yes _ No
6._X___ Trash Compactor:
7._X___ Refrigerator:
8.X____ Microwave: Magic chef
9.X____ Sink: Porcelain coated
10.X____ Electrical: 110 VAC GFCI
11.X____ Plumbing/Fixtures: unknown manufacturer
12.X____ Counter Tops: Laminate
13.X____ Cabinets: Wood
14.X____ Ceiling: Texture paint
15._X___ Walls: Paint - Wall covering is separating from the ceiling above refrigerator. This appears to be cosmetic.
16.X____ Floor: Hardwood
17.X____ Doors: Hollow wood
18.X____ Windows: Aluminum slider
19.X____ HVAC Source: Air exchange ventilation


Bedroom

A NP NI M D
Master Bedroom
1.X____ Closet: Two small, one in bathroom
2.X____ Ceiling: Texture paint
3.X____ Walls: Paint
4.X____ Floor: Carpet
5.X____ Doors: Hollow wood
6.X____ Windows: Aluminum double hung
7.X____ Electrical: 110 VAC GFCI
8.X____ HVAC Source: Air exchange ventilation and Ceiling fan
Second floor next to hall bathroom Bedroom
9.X____ Closet: Single small
10.X____ Ceiling: Texture paint
11.X____ Walls: Paint
12.X____ Floor: Carpet
13.X____ Doors: Hollow wood
14.X____ Windows: Aluminum slider
15.X____ Electrical: 110 VAC
16.X____ HVAC Source: Air exchange ventilation
Second floor second room east of hall bathroom Bedroom
17.X____ Closet: Single small - Attic access from closet
18.X____ Ceiling: Texture paint
19.X____ Walls: Paint
20.X____ Floor: Carpet
21.X____ Doors: Hollow wood
22.X____ Windows: Aluminum slider
23.X____ Electrical: 110 VAC
24.X____ HVAC Source: Air exchange ventilation
Northeast corner Bedroom
25.X____ Closet: Two Walk In
26.X____ Ceiling: Texture paint
27.X____ Walls: Paint
28.X____ Floor: Carpet
29.X____ Doors: Hollow wood
30.X____ Windows: Aluminum slider
31._X___ Electrical: 110 VAC - Overhead light is not working. Might be the bulb.
32.X____ HVAC Source: Air exchange ventilation


Living Space

A NP NI M D
Entry Living Space
1._X___ Closet:
2.X____ Ceiling: Texture paint
3.X____ Walls: Paint
4.X____ Floor: Hardwood
5.X____ Doors: metal
6.____X Windows: Aluminum casement - Water penetration noted around lower corners on the window above the front door
7.X____ Electrical: 110 VAC GFCI
8.X____ HVAC Source: Air exchange ventilation
Main floor family room Living Space
9._X___ Closet:
10.X____ Ceiling: Texture paint
11.X____ Walls: Paint
12.X____ Floor: Hardwood and carpet
13._X___ Doors:
14.X____ Windows: Aluminum double hung
15.X____ Electrical: 110 VAC GFCI
16.X____ HVAC Source: Air exchange ventilation
Dinning Room Living Space
17._X___ Closet:
18.X____ Ceiling: Texture paint
19.X____ Walls: Paint
20.X____ Floor: Hardwood
21.___X_ Doors: French - The door is sticking
22.X____ Windows: Aluminum double hung
23.X____ Electrical: 110 VAC GFCI
24.X____ HVAC Source: Air exchange ventilation
Main floor study Living Space
25._X___ Closet:
26.X____ Ceiling: Texture paint
27.X____ Walls: Paint
28.X____ Floor: Carpet
29.X____ Doors: Bi-fold
30.X____ Windows: Aluminum slider
31.X____ Electrical: 110 VAC
32.X____ HVAC Source: Air exchange ventilation
Basement study Living Space
33.X____ Closet: Two small
34.X____ Ceiling: Texture paint
35.X____ Walls: Paint
36.X____ Floor: Carpet
37._X___ Doors:
38.____X Windows: Aluminum slider - The window has dirt deposits in it from window well drainage.
39.X____ Electrical: 110 VAC GFCI
40.X____ HVAC Source: Air exchange ventilation
Upstairs Family Room Living Space
41._X___ Closet:
42.X____ Ceiling: Texture paint
43.X____ Walls: Paint
44.X____ Floor: Carpet
45._X___ Doors:
46.X____ Windows: Aluminum slider
47.X____ Electrical: 110 VAC
48.X____ HVAC Source: Air exchange ventilation
Upstairs Storage room Living Space
49._X___ Closet:
50.X____ Ceiling: Texture paint
51.X____ Walls: Paint
52.X____ Floor: Carpet
53.X____ Doors: Hollow wood
54._X___ Windows:
55.X____ Electrical: 110 VAC
56.X____ HVAC Source: Air exchange ventilation


Laundry Room/Area

A NP NI M D
1st Floor Laundry Room/Area
1.X____ Ceiling: Texture paint
2.X____ Walls: Paint
3.X____ Floors: Linoleum
4.X____ Doors: Hollow wood
5._X___ Windows:
6.____X Electrical: 110 VAC/220 VAC - GFCI is not working.
7.X____ HVAC Source: Air exchange ventilation
8._X___ Laundry Tub:
9.X____ Washer Hose Bib: Rotary
10.____X Washer and Dryer Electrical: 110-240 VAC - See electrical section under "panel"
11.X____ Dryer Vent: Metal flex
12.X____ Washer Drain: Wall mounted drain
13._X___ Floor Drain:

Marginal Summary

Exterior Surface and Components
Balance of surface other than front brick - Exterior Surface - Type: Vinyl siding - Some small holes and missing bits on back side of home.
South - Exterior Surface - Type: Brick veneer - Cracks on southwest corner above setting porch.
Entry Doors: Metal - Rear French door rubs and not sealed properly.

Roof
Valleys: Asphalt shingle - Ridge shingles are cracked, A qualified roofing contractor is recommended to evaluate and estimate repairs

Structure
Stairs/Handrails: Wood stairs with wood handrails - Upstairs hand rail loose.

Basement
Main - Basement - Windows: Aluminum slider - South west corner room window well needs to been dug out to allow proper drainage.
Main - Basement - Electrical: 110 VAC GFCI - One broken duplex cover by electrical panel
Main - Basement - Moisture Location: Tested all walls - Rear hose bib leaks into basement, A qualified contractor is recommended to evaluate and estimate repairs

Heating System
Basement - Heating System - Heating System Operation: Appears functional - No green sticker

Bathroom
2nd Floor Hall - Bathroom - Ventilation: Window -
Main level half bath - Bathroom - Ventilation: Window -

Kitchen
1st Floor - Kitchen - Disposal: Waste King - Makes noise like bad bearings

Living Space
Dinning Room - Living Space - Doors: French - The door is sticking

Defective Summary

Lots and Grounds
Porch: Concrete - Front porch is settling away from foundation. A qualified contractor is recommended to evaluate and estimate repairs
Window Wells: Drain not present - Well on west side is not deep enough for proper drainage.

Exterior Surface and Components
Exterior Electric Outlets: 110 VAC GFCI - Outlet at back door is not working.
Hose Bibs: Rotary - Rear bib is not working properly. Leaks into basement, A licensed plumber is recommended to evaluate and estimate repairs

Roof
Main - Roof Surface - Material: Asphalt shingle - Missing shingles, exposed felt paper, A qualified roofing contractor is recommended to evaluate and estimate repairs
West - Chimney - Chimney: Vinyl and frame covered three wall pipe - Broken vinyl, A qualified contractor is recommended to evaluate and estimate repairs

Electrical
240 VAC Branch Circuits: Copper - Dryer circuit shows sign of arcing under the electrical panel cover.
Smoke Detectors: Present on all finished levels of the home - These detectors appear to be the original equipment. They should be replaced. None in basement.
Basement main - Electric Panel - Manufacturer: Square D - Cracked insulation and signs of arcing on dryer circuit. Recommend further inspection by a qualified electrician.

Structure
Differential Movement: Crack with displacement - southwest corner of front porch.

Basement
Main - Basement - Walls: Concrete - Signs of water penetration on the north wall. This is from a leaking hose bib on the rear of the home.

Plumbing
Seizmic bracing None -

Bathroom
2nd Floor Hall - Bathroom - Tub/Surround: Cast iron tub and ceramic tile surround; - Drain stop not working

Living Space
Entry - Living Space - Windows: Aluminum casement - Water penetration noted around lower corners on the window above the front door
Basement study - Living Space - Windows: Aluminum slider - The window has dirt deposits in it from window well drainage.

Laundry Room/Area
1st Floor - Laundry Room/Area - Electrical: 110 VAC/220 VAC - GFCI is not working.
1st Floor - Laundry Room/Area - Washer and Dryer Electrical: 110-240 VAC - See electrical section under "panel"


Palm-Tech Inspector, Copyright 1998-2003, PDmB, Inc.

End of Report